7-10 PC Box VSB 40.1
DOK-SUPPL*-VSB*40.1***-PR02-EN-P
PC Power Supply
This screw connection is used for device variants for 24 VDC. All
internally required voltages are generated from the 24 VDC supply.
Anschluss24V.jpg
Fig. 7-10: Connection terminal for the 24 VDC supply
Note: Only copper wire is to be used to connect these terminals.
Tighten the screws of the screw terminals with a torque of 0.4
Nm (1.81 kg in).
Parameters Value
Input voltage U
N
24 VDC ; (19 ... 32 VDC)
Residual ripple for U
N
See figure on the following page
Power consumption for 19 VDC 20 A max.
Overload protection Deactivation with automatic restart
Short-circuit protection Deactivation with automatic restart
Fig. 7-11: Technical data 24 VDC connection