VSB 40.1 Technical Data 4-3
DOK-SUPPL*-VSB*40.1***-PR02-EN-P
4.4 Ambient Conditions
In operation Storage / Transport
Maximum ambient temperature
Exception: 230 V – UPS (see chapter 8.3)
+5 °C... +45 °C
+0 °C ... +40 °C
-20 °C to +60 °C
+0 °C ... +40 °C
Max. temperature gradient Temperature change up to 3°C
per minute
Not defined
Relative humidity Climatic class 3K3 according to
EN 60721, condensation not
permissible.
Climatic class 3K3 according to
EN 60721, condensation not
permissible.
Air pressure Up to 2 000 m above MSL
according to DIN 60204
Mechanical strength Max. vibration:
Frequency range: 10 ...
150 Hz
Excursion: 0.025 mm
for 10 ... 57 Hz
Acceleration: 0.25 g
for 57 ... 50 Hz
According to EN 60068-2-6
Max. shock:
5 g according to DIN IEC 68-2-
27, function not disturbed
Degree of pollution 2 2
Fig. 4-4: Ambient conditions
4.5 Used Standards
The system components of the industrial PCs correspond to the following
standards:
Standard Meaning
EN 60,204-1 Electrical equipment of machines
EN 50,081-2 Basic technical standard, noise immunity (industrial
environment)
EN 50,082-2 Basic technical standard, emitted interference
(industrial environment)
EN 60,742 Transformer for 24 V power supply unit, protective
separation
EN 60,950 Overvoltage category II
EN 61131 Requirements regarding 24V outputs
EN 61 131-2 Requirements on the 24 power supply
EN 418 Machine safety, EMERGENCY STOP devices
EN 60 529 Degrees of protection (incl. housings and installation
compartments)
EN 60 068-2-6 Vibration
EN 60 068-2-27 Shock
Fig. 4-5: Used standards
Note: Concerning delivered VSB 40.1 devices all CE requirements
are fulfilled. After plugging-in extension cards, however, a new
CE test has to be executed.
EN standards
CE Marking