7-8 PC Box VSB 40.1
DOK-SUPPL*-VSB*40.1***-PR02-EN-P
Keyboard Interface XKB
PS/2 Mini DIN female connector, 6-
pin
Cable length: 1.5 m max.
Cable type: Shielded, cross section min. 0.14 mm²
Keyboard Clock
Keyboard Data
GND
Mouse Data
Shield
Power, +5VDC
Mouse Clock
Keyboard
Shield applied to the metal housing
of the plug-in connector
max. 1.5 m
1
2
3
4
5
6
1
2
3
4
6
5
XKB
Tastatur_sst.FH9
Fig. 7-8: Keyboard interface
Note: If a VDP display is connected to a VSB 40, the keyboard can
only be connected to this one. The keyboard interface XKB at
the VSB 40.1 has to remain free.
Mouse Interface XMouse
PS/2 Mini DIN female connector, 6-
pin
Cable length: 1.5 m max.
Cable type: Shielded, cross section min. 0.14 mm²
Interrupt (IRQ): 12
BIOS presettings: PS/2 mouse support: Enabled
PS/2 mouse: Auto detect
Mouse Clock
Mouse Data
max. 1.5 m
Mouse
Power, +5VDC
Shield applied to the metal housing
of the plug-in connector
1
2
3
4
5
6
GND
Shield
XMS
Maus_sst.cdr
Fig. 7-9: Mouse interface XMS
If a PS/2 mouse is not recognized by the system, the mouse has to be
activated in the BIOS by switching from "Disabled" to "Autodetect". The
operating system will not recognize the plugging-in of an external mouse
XKB PS/2 Mini DIN Keyboard /
Mouse Interface
XMouse PS/2 Mouse Interface